Electrical fast transients (EFT), such as switching transients originating from inductive load interruption, relay contact bounce, etc., are one of the main causes of equipment malfunctions. Because they can occur anywhere interfering with circuits primarily via mains and interconnection cables.
EFT is characterized by fast rise times and a short duration of pulses. Also significant is the fact that EFT comes in bursts with repetition rates exceeding 100kHz. In the real world, an EFT event is a series of pulses with changing amplitudes and repetition rates. For test purposes, the IEC 61000-4-4 standard defines an idealized EFT/B. For anyone who wants to build quality products with an extensive test program from design, qualification, production to diagnostic purpose, the FNS-AX3 simulators will serve as a critical tool with a new level of performance and efficiency meeting and far exceeding the IEC standard requirements. 

                                Click to download the brochure


Output Waveform

Pulse waveform at rise-up
Pulse waveform at rise-up
Entire waveform
Entire waveform
Burst waveform
Burst waveform

Features

●A new level of ease of use with a touch-panel color LCD and screen design for intuitive settings, color graphical representation and good visibility.
●Three operation modes: IEC61000-4-4 STANDARD mode for an instant use. MANUAL mode for free setting including ramping. SEQUENCE mode for a seamless run of combined settings in Manual mode.
●4.8kV output at 2MHz pulse repetition rate assures the worst case testings.
●Valuable additional output modes: Polarity Reversal and Pulse Repetition Frequency Modulation modes are available.
●A wide variety of options
●A single package solution offering a generator and CDN
●Selection of single phase CDN rated 16A or three-phase CDN rated 50A
●Compliance to IEC/EN61000-4-4 Edition 2.0

Specification

Output voltage 200~4800V
 Polarity  Positive and negative
Output impedance
50Ω
Coupling mode
Common mode
Coupling capacitor / DC blocking capacitor
33nF/ 10nF
Pulse frequency*
0.1kHz~2MHz
Pulse waveform (at 50Ωload) *
Rise-up time 5ns±30% Pulse width 50ns±30%
Pulse waveform (at 1kΩ load) *
Rise-up time 5ns±30% Pulse width 35ns~150ns
Burst duration
1~1000 pulses (lmited depending on conditons)
Possible to set by time
Burst period
10ms~1000ms 10ms step
Continuous output function
Max. 10kHz (0.2~1kV)
Timer
1s~99h59m59s
Max. 10 min. when the pulse is
continuous and the polarity is switched
Operation mode
MANUAL / IEC LEVEL / SEQUENCE
Frequency modulation
Modulate pulse frequency between 0~-10% of setting
External trigger TTL
Down edge, minimum trigger interval acceptable 10ms~
Line synchronization
Asynchronized or synchronized with EUT(0~359° 1°step)
EUT power capacity
A16B : Single phase 3 lines AC85~240V 16A 50/60Hz
DC 125V 16A
Indicator / Operation panel
Color 5.7 inch touch panel LCD

Operating temperture /

humidity range

15~35℃ / 25~75% RH (without dew)
Power supply
AC100~240V 50/60Hz 120VA
Dimension
(W) 320x(D)352x (H) 400mm
Mass
Approx.14kg (A16 Single phase)
Approx. 19kg (B50 3-phase)

*Guaranteed accuracy range of waveform is 5~100kHz

1. Polarity reverse function

Enables to sweich for putting the positive pulse and negative one out per the one burst so as to enrich the test.

2. Pulse continuous output / Frequency modulation function

Functioning maximum 10 minutes continuous pulse and frequency modulation ( generate ''shaking'' in the frequency), which can be effective to reproduce the malfunction in the field.

Test Setup

Test Method using Fast Transient / Burst Simulator
(1) Place the simulator onto the ground place which is connected to the protective earth and connect SG terminal on the front panel to the ground plane.
(2) Connect power cable (Standard accessory) to AC IN on the back of the simulator.
(3) Place coupling adaptor CA-805B (Option) onto the ground place and connect G terminal on side connector part of the clamp to the ground plane.
(4) Connect PULSE OUT connector on the front of the simulator to connector of the adaptor.
(Fully pay attention to that any high voltage must not be put out during the connection)
(5) Thread cable to be tested through the adaptor.
(6) Set the test conditions like the coupling voltage, etc on the touch-panel on the front of the simulator and start the test.

Option


Coupling Adaptor MODEL: CA-805B (Capacitive coupling)

for INS-4020 / 4040, INS-AX2 Series and FNS-AX3 Series

Enable for testing characteristics against the noise only with clamping communication cables of electronics equipments in combination with INS Series.
○Enable to inject the noise without cutting signal, DC, AC, GND, etc.
○Enable to test the noise resistibility of electronics equipments separated individually.
○Realize to test the noise resistibility effectively since the injection can be directly to signal lines.
○Enable to clamp bundle of signal lines whose maximum diameter is 26mm

Input voltage : 4000V Max
Input pulse width :  50~1000ns
Dimension / Mass :
(W) 350 X (H) 120 X (D) 130mm / Approx 3kg
Storage temp. range :
-5~55℃
Inside clamp diameter :
26mm



Coupling Adaptor MODEL: 15-00007A (CA-806 / Magnetic field coupling)

for INS-4020 / 4040, INS-AX2 Series and FNS-AX3 Series

Enable for testing characteristics against the noise only with clamping communication cables of electronics equipments in combination with INS Series.
○Enable to inject the noise without cutting signal, DC, AC, GND, etc.
○Enable to test the noise resistibility of electronics equipments separated individually.
○Termination resistance built-in

Structure : Magnetic field coupling noise injection clamp
Input voltage : 2000V Max.
Input pulse width :  50~1000ns
Dimension / Mass : (W) 89 X (H) 64 X (D) 120mm / Approx. 1kg
Coupling ratio 1/10±10% of input voltage
Termination resistance : 50Ω system built-in
Max. ground cable diameter : 27mm

 


Coupling Probe MODEL: CA-803A

for INS-4020 / 4040, INS-AX2 Series and FNS-AX3 Series

Enable for testing characteristics against the noise only with clamping communication cables of electronics equipments in combination with INS Series.
○Enable to inject the noise without cutting signal, DC, AC, GND, etc.
○Enable to test the noise resistibility of electronics equipments separated individually.
○Enable to clamp bundle of signal lines whose maximum diameter is 15mm

Input voltage : 2000V MAX.
Input pulse width : 50~1000ns
Coupling ratio : 1/20±10% of input voltage
Dimension /
(W)160 × (H)60 × (D)35mm / Approx. 400g

 


Coupling Probe MODEL: 95242-1

for INS-4020 / 4040, INS-AX2 Series and FNS-AX3 Series

Produced by ETS LINDGREN
Enable for testing characteristics against the noise only with clamping communication cables of electronics equipments in combination with INS Series.

Frequency range : 10MHz - 400MHz                               
Maximumu input power : 100W
Maximum input current :  25A

 